how to change fan speed on a trane furnace

1

These blower motor versions can be found in furnaces, air handlers, and packaged units. View our Privacy Policy here. He owned and operated a manufacturing business building Compact Utility Vehicles for homeowner use. (Although it wouldn't hurt to record those too.) *NOTE* If you attempt this, be absolutely sure that you have no power going to your system, especially before changing wires. Then switch the jumper to your desired speed. That is incorrect. For homeowners who want to upgrade rather than replace an existing furnace, Emerson Electric offers an exclusive replacement blower motor called the Mark Z that can be set by the homeowner on a continuous, slower-than-normal speed. This BTU/HR capacity should be used to set the CFM for the indoor blower motor. I Tried a Hands-Free Dog Leash, and I No Longer Dread Walking My Dog, This Simple Trick Can Refresh Your Entire Home, 30 Spring Cleaning Tasks to Add to Your Checklist, Do not Sell or Share My Personal Information. During the awake hours I Hold the fan speed at either low or medium. Select your preferred wire with the warm temperature and connect it to the 'heat' port. He is also an HVACR Contracting Business owner of 16 years and holds an NJ HVACR Master License. . Stack Exchange network consists of 181 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers. A slim, removable cover will reveal the filter location. Locate the wire for the new speed setting ("medium" or "low"), remove the wire nut from its end and use wire strippers to strip 1/2-inch of insulation from the end of the wire. I understand that the higher speed is probably for cooling (for which we have a separate duct system and handler), but is it the case that the speed can be switched to a higher fan speed? If you do, you may not have enough air flow over the heat exchanger, resulting in overheating and eventually a shorter exchanger life span. I recently had have a trane xl 90 want to adjust speed of blower fan blower motor has 4 wires white going to neutral black unhooked blue to high speed yellow to I have a Trane Indoor Air Handler Model No. For more information, please see our He maintains fruit and nut trees along with helping his wife with a vegetable garden. Warmup.com mentions that it was the original design of radiant floor heat systems by the Romans. Is it suspicious or odd to stand by the gate of a GA airport watching the planes? Step 3. Remove the air handler. By pressing "submit", I understand that I am providing express consent for Trane Residential to contact me about this request or similar topics. Upon initial installation, these dip switches need to be adjusted for the particular unit, size, and application. Stage 3 Aux Heating. -The BTU/HR size is selectable between 48,000 42,000 36,000 or 30,000 BTU/HR. Various advertisements for variable speed high efficiency furnaces call them "more energy efficiency" (note also the difference between a variable speed blower and a high efficiency furnace, they're separate, for instance you can have a variable speed blower on a low efficiency furnace). The same is true when changing the air duct filter. Employment/Education Highlights Can you increase the speed of an ECM AC blower? 81K views 2 years ago In this video, we are changing the blower speed on a Trane XR 95 furnace so that the forced air furnace circulates more air on heat mode. I connected a second thermostat to the circuit board to run the blower (R to G). R and BK are tied together. These connected to (park) terminals, which are not used and simply hold those two additional wire speeds. Top Ten Interview Tips to Land that HVAC/R Job! Site design / logo 2023 Stack Exchange Inc; user contributions licensed under CC BY-SA. Based on some randomly googled comments here: http://www.inspectorsjournal.com/Forum/topic.asp?TOPIC_ID=8998& seems to agree it decreases efficiency but may increase comfort [ex: cold spots or noise level] :). I know that it has been done. If the ohm meter comes back with an open line reading, the switch is bad and needs replaced. Make sure power is off when doing any adjustment. with a wiring harness for the fan. Compatible with Trane systems or any standard HVAC system. If the pressure switch is functioning properly . @Dave: Those were my thoughts as well. Another key difference is that the circulate . The system also accounts for blocked vents and dirty furnace filters, and adjusts fan speed as needed to compensate. XB Trane Furnace: Is there a fan speed control on the unit. Where To Find R-22 & R410A Leaks on AC Units! Its not advisable to slow your furnace blower speed. I'm in the process of re-wiring my blower to run on high with the furnace. Note: (High voltage is always going to your blower motor along with the common for the 24 volts. If the instructions are not with the furnace, you can look up the model number of the unit and search for the installation manual via a google search. He has been DIY since childhood and is now a septuagenarian. This lower blower speed enhances However, I like the continually run the fan to even out air temperature in the house. Does that have any impact on the efficiency of the unit? ASE Certified Master Auto Technician Pollen, dust, clothing and carpet fibers, hair spray, mold spores, Pollen, dust, clothing and carpet fibers, hair, mold spores, legionella, pet dander, Pollen, dust, clothing and carpet fibers, hair spray, mold spores, bacteria, pet dander, cooking oil, most tobacco smoke, smog, Air filters are the first defense against the pollutants in your air, but building a complete air filtration system can help support an even higher quality of indoor air. Roughly 400 CFM is needed for every 1 ton (12,000 BTU/HR) of Heat Removal Capacity in Air Conditioning Systems. Browse other questions tagged, Start here for a quick overview of the site, Detailed answers to any questions you might have, Discuss the workings and policies of this site. There are only a few steps required for most units and having the control will allow you to get your unit to give you the service you need. I needed to go the opposite direction and increase fan speed. To recap: The service technician might be able to increase (or decrease) the blower speed, but that would probably lower the AC's cooling efficiency. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. Can airtags be tracked from an iMac desktop, with no iPhone? It is a Trane S8X1 single stage furnace and air handler, paired with an XR16 3 ton AC unit. Your AC or furnace is designed for a specific type of filter. In Dungeon World, is the Bard's Arcane Art subject to the same failure outcomes as other spells? Being an bms/controls guy I rarely have enough cfm in large buildings. To learn more, see our tips on writing great answers. It offers three settings: 525 RPM for saving energy, 900 RPM for heating, or 1100 RPM for air conditioning. If the blower motor is burned out, replace it. To start, ECM stands for Electronically Commutated Motor which means that the motor is capable of electronically controlling it's own speed, and therefore CFM, according to the desired output. But I'm reasonably sure it uses less to run on high vs low then it uses to run on low vs OFF. The control board is communicating with the blower module in order to determine the airflow volume needed. If a clear distinction between the blower speeds isn't obvious in the data, then you're probably not going to save much money either way, so go with what's most comfortable for you. Turn off power at the main electric panel. Sign up for our email newsletter to learn helpful HVAC tips and tricks before your purchase your system. HVAC filters help remove dust, dander, and harmful particles from the air inside your home. He is experienced in wood and metal construction, having designed and built several houses and metal buildings. Be sure to check out our previous article on "Adjusting the Furnace/AC Airflow Speed on a 120v PSC Blower Motor" if you haven't read it yet! I could imagine possibly fewer "warm up cycles" (which also include having to power on the fan) might save something (as well as lower fan speed=less electricity)but as others have noted, while its running (esp. *Based on third party testing of particle removal efficiency down to 0.3 microns (2005). Trane s9v2 should thermostat control blower speed? In the pictured example above, if the #5 speed tap is programmed for 1600 CFM and #4 is programmed for 1200 CFM and #5 is presently connected to the "Cool" terminal on the control board via the black wire, we know that the unit is running at around 1600 CFM as long as the TESP across the unit is not too high. Dave. Continue reading to learn how to lower the fan speed. I'll edit my answer and include the exact parameters I'd record every day for a thorough study. The blower is set for 400 cfm for a 4 ton outdoor unit, and comfort-R is not enabled (all factory). Website operating problems contact Webmaster. ECM Multi-Speed Blower Motor (Broad Ocean Type), For an ECM blower motor with wires exiting the module (shown above), the speed is changed at the control board by moving the colored wire terminals. Usually, gas furnaces have a temp rise of 50F. Design Engineer/Project Manager for injection molded plastic company For 240v units, both the L and N are hots. -The "AC/HP CFM Adjust" is the airflow volume to be set for system, efficiency, comfort. and as I recall, you have the HW VP IAQ stat. On this motor module, the speed wires are red, orange, blue, yellow, and black. Iappreciate all the comments, questions, and responses that Ireceive from each of you. Standard blower motors operate at a single speed and cost around $450 to replace, including parts and labor, while variable-speed motors cost $600 and up. The arrow should face the direction the air is flowing. Remove two screws from each bracket leg holding the motor. Switched it to heat (in which case the furnace board is in control of the fan, not the stat) - got fire, no fan. But I guess my question is, can the air flow problem really be a simple as upping the blower speed? Electric Furnace Sequencer Replacement Instructions for Home Repair Blower fan will not run: A failing sequencer may have a burnt contact and is unable to switch the fan and heating coils ON. Tools that we use: www.amazon.com/shop/acservicetech. I hope this helps you understand how to adjust the airflow speed on ECM Blower Motors! You may freely link to this site, and use it for non-commercial use subject to our terms of use.

Rowan County Judge Executive, What Became Of Barbara Graham's Children, Articles H